Page 2-1
Sequence of Operation
System Sequence of Events
Objective Equipment List
When perimeter motion is detected the system will speak Warning Protected Area, Leave Imme-
diately and turn on flood lights. The audible warning message will only be spoken when motion is
detected while the system is armed to Away but the flood lights will turn on whenever motion is de-
tected regardless of the arming mode if it is dark outside. The flood lights will turn off after a pro-
grammed time period.
Provide an
audible and a
visual warning
to an intruder
approaching
the perimeter
of a protected
area.
¨ Apex Destiny 6100 control panel, rev. 8.05 or greater
¨ X-10 PRO Power Line Interface Module, PSC05
¨ X-10 PRO Incandescent Wall Switch Module, PLW01
¨ X-10 PRO External Motion Detector, PHS01
(Settings: House code=M, Start Code=5, Time Delay=.1,
Sensor +1 Switch=IN, Dusk +5 Switch=IN)
1) When motion is detected PHSO1 transmits X-10 input signal 1 M6 ON (Also transmits X-10
input signal 2 M10 ON at sunset and M10 OFF at sunrise for Control Channel filters).
2) M6 ON X-10 signal activates Output Control assignment 1.
3) Output Control assignment 1 activates Control Channel 33(chain channel 1) and suppresses
speech.
4) Chain Channel Group 1 activates Control Channels 34, 35, 36.
5) Control Channel 34 activates Auxiliary Output pin 1 for two seconds if the system is armed to
Away applying a ground signal to Zone 16 input.
6) Control Channel 35 activates Auxiliary Output 8(on-board relay) for three seconds if the system
is armed to Away switching the external speaker to the internal speaker terminals.
7) Control Channel 36 transmits X-10 output signal H1 ON turning on the flood lights for 5
minutes.
8) Zone 16 activates and speaks Warning Protected Area Leave Immediately through external
speaker.
- Intruder Audible and Visual Warning -
- Application Note -
Home Control
Zobrazit stránku 21