- Sunrise / Sunset Lighting -
Sure Action Photo Cell, 12 volt
1) At sunset the photocell will provide a short circuit to activate Zone 16 and signal the system
that it is dark. At sunrise the photocell will remove the short circuit to restore Zone 16 and
signal the system that it is light.
2) At sunset the system sends an ON command to Control Channel 33 which sends an A1 ON
X-10 command to turn on the flood lights. Control Channel 33 will send an A1 OFF X-10
command to turn off the flood lights after the programmed countdown time.
3) Entering the front door with the system armed to Away or Home will cause the system to
activate the pre-alarm countdown. If it is dark the system will also send an ON command to
Control Channel 34. Control Channel 34 will send an A2 ON X-10 command to turn on the
hall lights. The hall lights will remain on until manually turned off.
Sequence of Operation
System Sequence of Events
Objective Equipment List
¨ Apex Destiny 6100 control panel, rev. 8.05 or greater
¨ X-10 PRO Power Line Interface Module, PSC05
¨ X-10 PRO Incandescent Wall Switch Module, PLW01 (qty 2)
¨ Sure Action 12VDC Photo Cell, SU-ON/OFF
Use a 12 volt
photocell to turn
on flood lights at
sunset and
provide lighted
pre-alarm entry
after sunset.
At sunset each day, the system will turn on the flood lights and automatically turn them off after
a specified time period. When pre-alarm is activated the system will turn on the hall lights to
provide lighted entry only if it is dark outside.