Zone Partition Report
68ZP
D...
00
CC
(CR-LF)
The panel sends this message in response to a Zone Partition Request.
The data portion of this message is 96 characters long, one character for each zone in order.
The value will be from 0-8, with 0 meaning no partition assignment.
Example: a Zone Partition Report for a system in which Zone 1 is assigned to Partition 2.
Zone 2 is assigned to no partition, and Zone 3 is assigned to Partition 8, would begin
68ZP208.…
5.4. System Word Messages
In all system word messages, the Data field is a 1-referenced 3-digit decimal number
corresponding to the number of the desired word.
Speak Word at Inside and Outside Speakers
0Bso
DDD
00
CC
(CR-LF)
Speak Word at Insider Speaker
0Bsi
DDD
00
CC
(CR-LF)
Speak Word Inside Speaker at Alert Volume
0Bsa
DDD
00
CC
(CR-LF)
Speak Word at Local Phone
0Bsl
DDD
00
CC
(CR-LF)
Speak Word at Remote Phone
0Bsr
DDD
00
CC
(CR-LF)
Example: Speak Word 123 at Inside Speaker is 0Bsi12300BC(CR-LF)
5.5. Control Channel Messages
You can use your PC to send an on or off command to a control channel. The control
channel programming determines which outputs are controlled and what action occurs.
The data portion of the channel on and off commands is a 2-digit, 1-referenced decimal
number corresponding to the number of the desired control channel
You can also query the panel concerning control channel status with a Control Channel
Status Request. The panel will respond with a Control Channel Status Report.
Control Channel On
0Acn
DD
00
CC
(CR-LF)